{"id":595538,"date":"2025-11-03T14:04:01","date_gmt":"2025-11-03T13:04:01","guid":{"rendered":"https:\/\/augustin-entsorgung.de\/services\/sewer-industrial-and-street-cleaning\/tightness-testing\/"},"modified":"2026-10-23T16:30:08","modified_gmt":"2026-10-23T14:30:08","slug":"tightness-testing","status":"publish","type":"page","link":"https:\/\/augustin-entsorgung.de\/en-2\/services\/sewer-industrial-and-street-cleaning\/tightness-testing\/","title":{"rendered":"Tightness Testing"},"content":{"rendered":"\n<div class=\"wp-block-group alignfull has-base-3-background-color has-background\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<div style=\"height:80px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\" id=\"dichtigkeitspruefungen\">Tightness Testing<\/h2>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">However, our rehabilitation vehicles are not exclusively used for rehabilitation; we also perform tightness tests on newly installed or rehabilitated drainage systems. This is generally done in accordance with DIN EN 1610. <\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Tightness tests can be performed with air as a pressure or vacuum test, as well as with water.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Sewer sections are sealed airtight at the end and at the connection lines with inflatable stoppers. Overpressure or underpressure is applied to the section via a test element. Depending on the material, nominal diameter, and length of the section, this pressure must be maintained for a specified time to classify the line as tight. All measurement and control processes are fully automated by the system.   <\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">The program generates a measurement report as proof for the client. All probes and measuring instruments undergo annual calibration to continuously ensure accurate results and, consequently, impeccable quality. <\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-text-align-center\">Tightness Testing After CIPP Rehabilitation<\/h3>\n\n\n<div class=\"gb-container gb-container-e90a52d9\">\n\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>Performing tightness tests after rehabilitation with a CIPP liner<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">After the liner rehabilitation is complete, a <strong>tightness test with air<\/strong> is performed.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Before the <strong>tightness test<\/strong> can be carried out in the sewer after rehabilitation, the sewer must be thoroughly cleaned using a flushing nozzle.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">To test the tightness of a rehabilitated sewer, extensive <strong>special equipment<\/strong> is required.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">The sewer section to be tested is first sealed off using test stoppers. Pressure hoses are connected to the stopper and the test unit. The pressure test unit contains a computer with special software storing all DIN standards for pressure tests. After selecting the standard, the test program begins computer-controlled. This prevents procedural errors by the test operator. Sensors in the test unit then determine whether the pipeline meets the test criteria according to DIN.    <\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"490\" height=\"240\" src=\"https:\/\/augustin-entsorgung.de\/wp-content\/uploads\/2023\/09\/Dichtheitspruefung-01.jpg\" alt=\"\" class=\"wp-image-586887\" srcset=\"https:\/\/augustin-entsorgung.de\/wp-content\/uploads\/2023\/09\/Dichtheitspruefung-01.jpg 490w, https:\/\/augustin-entsorgung.de\/wp-content\/uploads\/2023\/09\/Dichtheitspruefung-01-300x147.jpg 300w\" sizes=\"(max-width: 490px) 100vw, 490px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"488\" height=\"237\" src=\"https:\/\/augustin-entsorgung.de\/wp-content\/uploads\/2023\/09\/dichtheitspruefung-02.png\" alt=\"\" class=\"wp-image-586888\" srcset=\"https:\/\/augustin-entsorgung.de\/wp-content\/uploads\/2023\/09\/dichtheitspruefung-02.png 488w, https:\/\/augustin-entsorgung.de\/wp-content\/uploads\/2023\/09\/dichtheitspruefung-02-300x146.png 300w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">After the test is completed, the <strong>test result<\/strong> can be immediately printed as a graphical representation in the pressure measurement diagram, allowing for on-site determination of whether tightness was confirmed for the section being tested.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Wastewater sewers must be tight. Leaky wastewater sewers pollute groundwater and soil. The <strong>water tightness<\/strong> of wastewater sewers and pipes must be ensured according to the test requirements of DIN EN 752-2.  <\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">The standard procedure is tightness testing in pipes and manholes with air. Optionally, tightness testing can also be performed with water. <\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">All essential test standards for the testing application are stored in the test unit&#8217;s computer, thereby simplifying the preparation and execution of the pressure test.<\/p>\n\n<\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Tightness Testing However, our rehabilitation vehicles are not exclusively used for rehabilitation; we also perform tightness tests on newly installed or rehabilitated drainage systems. This is generally done in accordance with DIN EN 1610. Tightness tests can be performed with air as a pressure or vacuum test, as well as with water. Sewer sections are &#8230; <a title=\"Tightness Testing\" class=\"read-more\" href=\"https:\/\/augustin-entsorgung.de\/en-2\/services\/sewer-industrial-and-street-cleaning\/tightness-testing\/\" aria-label=\"Read more about Tightness Testing\">Weiterlesen &#8230;<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":595205,"menu_order":6,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"categories":[],"tags":[],"class_list":["post-595538","page","type-page","status-publish"],"acf":[],"_links":{"self":[{"href":"https:\/\/augustin-entsorgung.de\/en-2\/wp-json\/wp\/v2\/pages\/595538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/augustin-entsorgung.de\/en-2\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/augustin-entsorgung.de\/en-2\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/augustin-entsorgung.de\/en-2\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/augustin-entsorgung.de\/en-2\/wp-json\/wp\/v2\/comments?post=595538"}],"version-history":[{"count":1,"href":"https:\/\/augustin-entsorgung.de\/en-2\/wp-json\/wp\/v2\/pages\/595538\/revisions"}],"predecessor-version":[{"id":595539,"href":"https:\/\/augustin-entsorgung.de\/en-2\/wp-json\/wp\/v2\/pages\/595538\/revisions\/595539"}],"up":[{"embeddable":true,"href":"https:\/\/augustin-entsorgung.de\/en-2\/wp-json\/wp\/v2\/pages\/595205"}],"wp:attachment":[{"href":"https:\/\/augustin-entsorgung.de\/en-2\/wp-json\/wp\/v2\/media?parent=595538"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/augustin-entsorgung.de\/en-2\/wp-json\/wp\/v2\/categories?post=595538"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/augustin-entsorgung.de\/en-2\/wp-json\/wp\/v2\/tags?post=595538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}